Aug 18, 2017 This part include some content about BMW INPA software or cable working cases on BMW E60. BMW INPA Reset BMW E60 Airbag Waring Light. How to Reset & Relearn E60 BMW Automatic Transmission with INPA. BMW E60 Coding by INPA and NCS Expert Cable. For more about BMW INPA E60,please check:BMW INPA E60 Coding/Diagnose Guide. Scanner INPA K + D-can is used for a full-featured professional diagnostics cars BMW, MINI and Rolls-Royce, adaptation units and units, coding, programming. Adapter INPA K + Dcan connected to the car via K-line or CAN-bus data transfer that allows you to work with any electronic control unit of the vehicle. K+DCAN USB cable is verified to work no issues with INPA BMW. It’s the newest K+DCAN cable, released in the 2016 year with two new futures: Feature 1: 2016 new k+dcan cable adds a switch on the adapter. The switch on this cable to LEFT is for 7 pin, to RIGHT for 8 pin. 8 pin for K-LINE communication (old DCAN cables cannot do it) for BMW from.

This article is on how to update your BMW Inpa USB K+Dcan cable with enhanced firmware which improves communication speed and guards against corrupt ECU flashes!

How to open rcf file. The items to use:

Besides one of the workable USB K+CAN cables listed later, you will need the following items:

  1. Arduino Uno (R3, doesn’t matter) or other model Arduino – $3.65
  2. Dupont or Arduino jumper wires (male to female) – $1.33 for 40
  3. 2.54mm breakout pins (6 pins total) – $1.13
  4. Soldering iron/solder (if flashing a generic USB cable with switch that has empty ISP pinouts)

The software to download first:

you will need two programs and the newest firmware file to flash the required software to the Arduino and cable.

Software:

 ARDUINO IDE: https://www.arduino.cc/en/main/software

 AVRDUDESS: http://blog.zakkemble.net/avrdudess-a-gui-for-avrdude/

Firmware:

Newest Ediabaslib Binary cable Firmware:

Credits to Ulrich Holeschak who developed this firmware and documented

the procedure for use with his open source Ediabaslib.

Enhanced firmware advantages:

  1. Can flash the following BMW ECUs without corruption:

 M3/M5/M6 DME (MSS6X)

 E6x M5/M6 SMG (GDSMG3)

 E9x GM Auto (GM1912)

  1. And more…
Software

 Faster CAN communication (block size 0 and no separation time).

 Allows configuration of CAN mode all the time, not only after power on.

 Allows configuration of the CAN parameters (block size and separation time)

 Correctly displays the ignition status (only available for K-line mode).

 Contains a bootstrap loader that allows firmware update without opening the device.

 Reduced power consumption due to use of sleep mode.

Workable cables:

We tested 2 kinds of Inpa K+CAN cable based on ATMega162 board can be flashed with this updated firmware, we are not responsible for any other cables that are not listed below.

  1. ONESTOP Cable with ISP header: No soldering required
  1. Generic AtMega162 based USB INPA cable with switch and ISP headers on circuit board: Soldering of header pins required

Before ordering INPA USB cable, Verify with the seller that the cable does have the ISP pin

header.

Look at the images below, the circuit board with pin header that we have already soldered on. The stock cable will not include the male pin headers, but rather empty holes which will allow you to solder on your own pins.

How to install the software for Inpa K+CAN cable?

STEP 1: Install software programs and download latest firmware

Inpa

After downloading the files listed earlier in this document, install all of them using the default options.

Notes:

Arduino IDE:

When the Arduino IDE asks if you want to install any drivers from ADAfruit industries, select yes

or OK. It will prompt multiple times, but continue to agree to the driver installations.

AVRDUDESS:

Allow AVRDudess to put an icon on your desktop

Binary firmware:

Extract file with your favorite .zip archive extracting utility and save it to a folder on your

desktop.

Configuring the Arduino

STEP 2: Connect the Arduino to PC using supplied USB cable

  1. After installing the software above, plug in your Arduino to the computer using the supplied USB cable.

Windows will detect and install the driver for the device.

Good to know:

if it does not and it shows that windows has failed to install a driver, download and

install the driver from the following link (CH341 based Arduino boards):

  1. Verify the com port of the Arduino:
  2. Open up windows device manager and expand the ports tree to view the Arduino com

port designation (COM5). Make note of this for the next step.

STEP 3: Flash Arduino as programmer

  1. Run the Arduino IDE application and click OK to any prompts that show (java/firewall).
  2. Click the TOOLS menu > BOARD > and select the Arduino board you have (be it Arduino Uno,

mega, etc).

  1. Click the TOOLS menu > PORT > and select the COM port you made note of in the previous step (In this example its COM5).

Next, click on the FILE menu > Examples > 11.ArduinoISP >ArduinoISP

It will open up a new IDE window containing the code which we will upload to the Arduino.

Finally, Click the Arrow button (next to the checkmark circle) highlighted (in white) in the image below.

Clicking the Upload button will then begin to compile the sketch, and when done will tell you it is “Done uploading”.

You may now close the Arduino IDE. The Arduino is now an Atmel programmer!

Connecting the Arduino to The Inpa K+Can Cable ISP Pin Header

Connect Arduino to USB cable using jumper cables

For this step you will reference the images in this document and table below to see the correct pinout designations for the type of cable you are trying to flash. It’s imperative you connect the correct pins on the Arduino to the correct pins on the cable you are trying to flash. Failure to do so will prevent the flash from completing successfully. Bear in mind it makes no difference the color of the wires, as long as the pin number on the Arduino matches the Pin designation on the ISP header on the USB cable you are trying to flash.

One stop electronics cable

Generic cable with Switch and ISP Breakout

STEP 5: Flash cable with enhanced firmware

Verify:

  1. The Arduino and USB cable are correctly connected together via jumper cables
  2. The Arduino is connected to the computer by USB cable

*Optional: Plug the USB cable into the computer to supply it with power (it isn’t necessary to

install any drivers for it).

Once the above has been verified, run the AVRDUDESS application and configure the options exactly as

shown below:

Programmer (-c): Atmel AVR ISP

Port (-P): COM PORT YOU NOTED ABOVE (COM 5 in this example)

Baud rate (-b): 19200

Bit clock (-B): blank

Bmw inpa k dcan software

Presets: Default

2006 suzuki ltr 450 owners manual. Options: Uncheck all (none selected)

Fuses lock bits:

L : 0xFD

H : 0xDC

E : 0xF9

Set Fuses: CHECKED

LB: BLANK

Once the AVRDUDESS options have been set:

  1. Click the detect button at the top right corner to verify the Arduino can communicate with the

USB Cable microcontroller. If everything is connected properly, it should detect and specify the

chip in the terminal window and populate the MCU (-p) options with the correct

microcontroller.

If AVRDUDESS cannot detect the correct chip, verify the Arduino to ISP header connections and

double check soldering points.

  1. Next, set the cable fuses by clicking the WRITE button directly under the ‘Fuses Lock Bits’

heading. This will write the three fuses we specified earlier to the cable. AVRDUDESS will also

display a terminal message verifying the fuses as shown below.

  1. Next, under the FLASH section of AVRDUDESS, click the ‘…’ next to the empty space to browse

and select the ‘Combined.hex’ firmware file located in the CanAdapter folder from the archive

you extracted from the latest binary file located at

  1. Verify that the Write radio button is selected, and Auto (writing only) is selected from the

Format drop down selection.

  1. Click ‘Go’ to begin the flashing process.

At the end of the flash, the LED may light up on the USB cable.

That’s all.

Your Inpa K+CAN Cable is new upgraded with enhanced firmware.

Original resource: https://cartechnology.co.uk/showthread.php?tid=86203

Related posts:

Note: Communication with the BMW DCT TCU (only) is not possible with BMW ISTA!

Needed hardware for BMW diagnostics

Product

Price

Note

85USD

Slow slow slow shipment, but the only D-CAN cable we have tested that actually works. Firmware flashing OK with this one.

45USD

Slow slow slow shipment, sometimes issues with TCU firmware flashing, works OK for diagnostics.

OlaO INPA K-DCAN (Swedish)

45USD

Superfast shipment (Sweden). Works ok for diagnostics, but will not work for TCU firmware flashing.

Note: Internet is sooo flooded with copies of this D-CAN cable, so we had a hard time find the original one..

Note: Fully working INPA + tools are available for download on bimmergeeks download section, just make sure to follow their isntallation instructions to 100%.

Bmw Inpa K Dcan Software Download

Needed software/tools for BMW diagnostics/flashing

Product

Note

BMW INPA

Used for diagnostics.

BMW Coding tool

Update SP daten files on your computer.

Unknown device driver windows 10 64 bit. Winkfp

To flash the 'GTS' firmware to the M3 TCU.

Read installation instructions really really carefully.

Bmw inpa k dcan software online

How to read the E9x M3 DCT TCU using a K+ DCAN USB interface.

What Is Bmw Inpa Software

Note: Make sure you have a good battery, and a good battery charger connected while performing the TCU firmware update, otherwise your TCU can get permanently unusable.

1. You need a working INPA compatible USB K+ DCAN interface.

Note: Insert DCAN interface in OBD port, IGNITION on, insert USB in laptop, start INPA, in that order to make it all work.

2. Verify communication with the TCU by starting INPA software and do a UIF readout of your TCUs original ZB number, and save it.

Note: Make sure your latency is changed to 1 ms in windows control panel --> device manager, com-port settings, also it only works on COM1 port..

This is the only INPA option you can connect with, if you don't have this under Transmission, your INPA installation is not correct and needs to be updated to have the E89/E90 files.

Read status value from BMW INPA

Bmw Inpa / Ediabas K+dcan Usb Interface Software Download

1. Press the status button.

2. Press the analog or digital button here, in our example we check analog values.

How To Use Inpa Bmw Software

3. In this example we press F1 to see the most essential values.

4. You now see a bunch of analog values from your TCU, some of them are from MaxxECU CAN, some of them are internal values.

5. This view gives you information about the individual clutch pressures, torque transmitted from MaxxECU, and the actual torque calculated by the TCU over each clutch.

Note: The INPA tool is mostly used to check for DCT error codes, and make sure all engine values are correct and sane.